Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1974 1
1977 4
1978 2
1982 1
1990 1
2001 1
2003 1
2004 1
2005 1
2008 2
2009 1
2010 1
2011 1
2012 1
2014 1
2015 1
2016 5
2017 2
2018 2
2019 2
2020 2
2021 6
2022 2
2023 2
2024 2

Text availability

Article attribute

Article type

Publication date

Search Results

40 results

Results by year

Filters applied: . Clear all
Page 1
A new intra-oral screw jack.
McMillan DR, Tryde G, Stoltze K, Fujii H, Kato H, Brill N. McMillan DR, et al. J Oral Rehabil. 1977 Apr;4(2):119-24. doi: 10.1111/j.1365-2842.1977.tb00973.x. J Oral Rehabil. 1977. PMID: 266048
Laboratory experiments were contrived to define the magnitude of reading errors and the play in the screw threads. It was found that, only in instances where a graduation related closely to the datum mark, did errors of interpretation arise. ...Mean play in the new pattern …
Laboratory experiments were contrived to define the magnitude of reading errors and the play in the screw threads. It was found that, …
Review of mechanisms of expandable spine surgery devices.
Mao Y, Patel AA, Meade S, Benzel E, Steinmetz MP, Mroz T, Habboub G. Mao Y, et al. Expert Rev Med Devices. 2024 Apr 1:1-10. doi: 10.1080/17434440.2024.2337295. Online ahead of print. Expert Rev Med Devices. 2024. PMID: 38557229 Review.
Five major types of mechanical jacks that drive expansion were identified: scissor, pneumatic, screw, ratchet, and insertion-expansion. EXPERT OPINION: We identified a trend of screw jack mechanism being the predominant machinery in vertebral body reconstruct …
Five major types of mechanical jacks that drive expansion were identified: scissor, pneumatic, screw, ratchet, and insertion-expansio …
The Modified Iliac Screw: An Anatomic Comparison and Technical Guide.
von Glinski A, Yilmaz E, Ishak B, Hayman E, Ramey W, Jack A, Iwanaga J, Oskouian RJ, Tubbs RS, Chapman JR. von Glinski A, et al. World Neurosurg. 2020 Apr;136:e608-e613. doi: 10.1016/j.wneu.2020.01.091. Epub 2020 Jan 23. World Neurosurg. 2020. PMID: 31981785
Soft tissue coverage and midline distance in an MIS and a traditional iliac screw were compared. METHODS: Two different variations of iliac screws were placed into 12 fresh frozen adult cadavers (9 male, 3 female, mean age at death 77.08 years, mean body mass index …
Soft tissue coverage and midline distance in an MIS and a traditional iliac screw were compared. METHODS: Two different variations of …
Neurovascular Relations in Modified Iliac Screws and Traditional Iliac Screw: Anatomic Study.
von Glinski A, Yilmaz E, Ishak B, Ramey W, Jack A, Iwanaga J, Abdul-Jabbar A, Oskouian RJ, Tubbs RS, Chapman JR. von Glinski A, et al. World Neurosurg. 2020 Feb;134:e93-e97. doi: 10.1016/j.wneu.2019.09.090. Epub 2019 Sep 25. World Neurosurg. 2020. PMID: 31562967
We measured the screw-to-supragluteal artery, vein, and nerve (SGANV) bundle and screw-to-sciatic notch distances. ...The SGANV bundle-to-MS distance was 20.6 mm, and SGANV bundle-to-TS distance was 20.77 mm, again an insignificant difference. CONCLUSIONS: Using the …
We measured the screw-to-supragluteal artery, vein, and nerve (SGANV) bundle and screw-to-sciatic notch distances. ...The SGAN …
Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study.
Smith JD, Jack MM, Harn NR, Bertsch JR, Arnold PM. Smith JD, et al. Global Spine J. 2016 Jun;6(4):344-9. doi: 10.1055/s-0035-1563723. Epub 2015 Sep 21. Global Spine J. 2016. PMID: 27190736 Free PMC article.
Outcome measures included screw accuracy, neurologic status, radiation dosing, and surgical complications. Results Four patients had fusion at C1-C2 only, and in the remaining three, fixation extended down to C3 due to anatomical considerations for screw placement r …
Outcome measures included screw accuracy, neurologic status, radiation dosing, and surgical complications. Results Four patients had …
Current concepts of spondylosis and posterior spinal motion preservation for radiologists.
Porrino J, Rao A, Moran J, Wang A, Grauer J, Haims A, Kani K. Porrino J, et al. Skeletal Radiol. 2021 Nov;50(11):2169-2184. doi: 10.1007/s00256-021-03840-6. Epub 2021 Jun 15. Skeletal Radiol. 2021. PMID: 34131792 Review.
In the lumbar spine, motion-sparing systems include interspinous process devices (also referred to as interspinous process spacers or distraction devices), posterior dynamic stabilization devices (also referred to as pedicle screw/rod fixation-based systems), and posterior …
In the lumbar spine, motion-sparing systems include interspinous process devices (also referred to as interspinous process spacers or distra …
Calcaneotibial screws for immobilisation of the tarsocrural joint of dogs in extension: effect of the angle of screw placement on the force to failure in a canine cadaveric model.
Devereux S, Jack M, Worth A, Bridges J. Devereux S, et al. N Z Vet J. 2021 Sep;69(5):294-298. doi: 10.1080/00480169.2021.1931522. Epub 2021 Jun 6. N Z Vet J. 2021. PMID: 34013827
AIMS: To compare the force to failure under axial loading of a calcaneotibial screw placed approximately perpendicular to the tibia with that of a screw placed perpendicular to the calcaneus, when used to immobilise the tarsus in an ex vivo canine model. ...Placing …
AIMS: To compare the force to failure under axial loading of a calcaneotibial screw placed approximately perpendicular to the tibia w …
Biomaterials, biomechanics, tissue healing, and immediate-function dental implants.
Lemons JE. Lemons JE. J Oral Implantol. 2004;30(5):318-24. doi: 10.1563/0712.1. J Oral Implantol. 2004. PMID: 15587023 Review.
Available information introduces more questions than answers, and recommendations are made for ongoing studies of bone responses specific to the implant fit and fill parameters focused on the kinetics of postsurgical osteotomy healing and applied loading. The clinical lite …
Available information introduces more questions than answers, and recommendations are made for ongoing studies of bone responses spec …
Comparing the fixation of a novel hollow screw versus a conventional solid screw in human sacra under cyclic loading.
McLachlin SD, Beaton BJ, Sabo MT, Gurr KR, Bailey SI, Bailey CS, Dunning CE. McLachlin SD, et al. Spine (Phila Pa 1976). 2008 Aug 1;33(17):1870-5. doi: 10.1097/BRS.0b013e3181808c75. Spine (Phila Pa 1976). 2008. PMID: 18670340
Overall, the hollow screw required fewer loading cycles (P = 0.004) and less applied moment (P = 0.003) to achieve the same magnitude of screw rotation as the solid screw. To achieve 6 degrees of screw rotation, the number of loading cycles were 6301 + …
Overall, the hollow screw required fewer loading cycles (P = 0.004) and less applied moment (P = 0.003) to achieve the same magnitude …
40 results